2094000700
CONTROL TRIGGER BOX FOR THREE ACTUATORS
The trigger box is built to control three MICRO S electric actuators. Control is made
through a dedicated keyboard that can be connected with a three-pole cable.
The keyboard and remote control input lets you simply connect up to 10 keyboards in
parallel with distances ranging up to 50 meters.
The trigger box has a current absorption system for stopping the motors' movement.
The limit switches' intervention threshold can be adjusted with a trimmer inside the box.
It is possible to connect up to 5 trigger boxes to each other to obtain the simultaneous
control of several actuators through only one keyboard. This function is attained by
simply connecting, in parallel, the three poles of the keyboard input of all the boxes
and putting the switch in the MASTER (ON) mode for the first box and in the SLAVE (OFF)
mode for all those that follow.
The control trigger box has an input for the rain sensors that permit automatic activation
of the window frame's closing in the case that the sensor comes into contact with rainwater.
This function can be activated or not for each individual output through 3 switches.
SPECIFICATIONS
- 24V DC POWER FROM POWER SUPPLY UNIT.
- POWER SUPPLY CONNECTION WITH 2-POLE, 1-MM SECTION CABLE WITH MAX. 5-M LENGTH
- 5MA ABSORPTION WITH MOTORS OFF
- OPERATING TEMPERATURE 0 50°C
- OVERALL MECHANICAL DIMENSIONS OF 85 X 135 X 30 MM
- CONNECTION OF ACTUATORS WITH 2 X 0.75 MM SECTION CABLE WITH MAX. 20-M LENGTH (INCREASE CABLE SECTION FOR GREATER DISTANCES)
- CONNECTION TO KEYBOARD WITH 3-CONDUCTOR, 0.22-MM SECTION CABLE WITH MAX. 20-M LENGTH
- POSSIBILITY TO CONNECT UP TO 5 CONTROL TRIGGER BOXES (1 MASTER + 4 SLAVES) IN PARALLEL
|

|
2094001000
WALL-MOUNTED KEYBOARD FOR THREE MOTORS
2094001100
FLUSH-MOUNTED KEYBOARD FOR THREE MOTORS
The serial keyboard has 9 keys that let you transmit the OPEN, STOP and CLOSE commands to
the control trigger box. Up to 10 keyboards can be connected in parallel on the same line.
The serial line uses a protocol that is very safe (cannot be duplicated) and that is highly
reliable.
SPECIFICATIONS
- POWER SUPPLY RECEIVED DIRECTLY FROM THE 3-POLE SERIAL LINE
- IMMUNITY TO 4KV DISTURBANCES
- OPERATING TEMPERATURE 0¸50°C
- IP 53 DEGREE OF PROTECTION
- FRONT IN SCRATCHPROOF POLYCARBONATE
- OVERALL MECHANICAL DIMENSIONS OF 75 X 105 X 30 MM (MI203/TP)
- RUBBER GASKETS SUPPLIED
- CONNECTION WITH 3-POLE, 0.22-MM SECTION CABLE WITH MAX. 50-M LENGTH
|
|
2094000800 POWER SUPPLY UNIT FOR THREE MOTORS
The power supply unit supports a trigger box with a maximum of 10 keyboards connected to it.
SPECIFICATIONS
- INPUT 230V~ +/-20%
- OUTPUT 24V DC
- FUSE 500 mA OPERATING TEMPERATURE 0 ¸ 50°C
|
|
2094000900
BATTERY UNIT / NiCd BATTERY CHARGER
The battery unit guarantees functioning of the system in its entirety even when
power supply from the mains is absent. Under these conditions, 30 opening/closing
movements are guaranteed. It is connected to the trigger box through a 2-pole,
1-mm section cable. The pilot lamp located on the printed circuit, when lit,
shows that the battery unit is being recharged.
SPECIFICATIONS
- BATTERY UNIT VOLTAGE 18V DC
- RECHARGE CURRENT 20 Ma
- TOTAL RECHARGING TIME 48 h
- MAX. CAPACITY WITH MOTORS TURNED OFF > 50 h
- OVERALL MECHANICAL DIMENSIONS 85 X 135 X 30 mm
|
|
2094001300
PORTABLE INFRARED TRANSMITTER
2094001200
INFRARED RECEIVER MODULE
The portable transmitter lets you activate the movements of the three actuators
connected to the trigger box. The receiver module supplied together with the
transmitter is to be installed on the keyboard connected to the system by simply
plugging it into the 3-pole, 2.54-mm pitch terminal board. To install on the
keyboard itself.
SPECIFICATIONS
POWER SUPPLY 12V BATTERY MODEL GP 23A (ALKALINE)
RANGE 6 M
RADIUS OPENING 10°
BATTERY LIFETIME 7000 OPERATIONS (MEMORISED MODE)
OPERATING TEMPERATURE 0 ¸ 50°C
DIMENSIONS 105 X 58 X 18.5 MM
|
|
2094001400
RAIN DETECTOR
The rain detector's function is to communicate the event to the trigger box. The trigger
box should then automatically close the window frames in case of rain. For each motor,
there is the possibility to activate or deactivate the automatic operation in combination
with the rain sensor through the relative switches in the trigger box. To be activated,
the sensor must actually be dampened and therefore must be installed in a position exposed
to the rain.
SPECIFICATIONS
DIRECT POWER SUPPLY FROM THE TRIGGER BOX (2-POLE CABLE)
CONSUMPTION: 0.5 mA OFF AND 10 mA ON
OPERATING TEMPERATURE -10° + 50°C
|
|
2094001500
POWER SUPPLY UNIT FOR A SINGLE ACTUATOR
The power supply unit permits motorization control from a local push button panel located
near the frame that is to be operated. The remote control can be timed and can also come
from a rain detector, wind detector or another type of detector which, when activated,
determines the opening or closing of the frame. There are therefore two inputs for the
controls, and one has priority on the other one. As a result, if the local control is abutted
on the priority input, it will determine the opening or closing aside from whatever command
arrives from the remote control, and vice versa. The opening or closing movement will take place
when the corresponding key is kept pressed for the entire duration of the movement. The limit switch
system is the current absorption type and the intervention value is adjustable between 300 and 900 mA
(through a trimmer situated on the card close to the relays) so as to satisfy the various weight or
friction conditions consistent with the users' safety.
SPECIFICATIONS
POWER SUPPLY 230V~
ABSORPTION MAX. 950 Ma
OPERATING TEMPERATURE 0 ÷ 50°C
OVERALL MECHANICAL DIMENSIONS 85 X 135 X 30 MM
POWER SUPPLY CONNECTION WITH 2-POLE, 1-MM SECTION CABLE WITH MAX. 5-M LENGTH
ACTUATOR CONNECTION WITH 0.75-MM SECTION CABLE WITH MAX. 20-M LENGTH (INCREASE CABLE SECTION FOR GREATER DISTANCES)
CONNECTION TO THE KEYBOARD WITH 3-CONDUCTOR, 0.22-MM SECTION CABLE WITH MAX. 50-M LENGTH
CONNECTION TO RAIN SENSORS WITH 2-POLE, 0.22-MM SECTION CABLE WITH MAX. 20-M LENGTH
POSSIBILITY TO CONNECT UP TO 5 TRIGGER BOXES IN PARALLEL.
|